Starting the Engine
EMS (Engine Management System)
The pre-heating time is adjusted to suit the engine
temperature, and can last for up to 50 seconds both
before and after starting.
The starter motor connection time is maximized to 20
seconds. After that, the starter motor circuit is cut for
80 seconds to protect the starter motor against over-
heating.
DCU (Display Control Unit)
With pre-heating
1 Depress the ON/OFF-button (6).
2 Press the SEL button (8) to come to the main-
menu.
3 Scroll down to Pre/heater with scroll button
(7),press SEL-button (8)
4 In the pre-heater menu, press the SEL-button
(8) to select pre-heating.
5 Press the START- button (2).
Without pre-heating
1 Depress the ON/OFF-button (6).
2 Press the START-button (2).
Leave the engine to idle for the first 10 seconds. Then
warm the engine up at low speed and under low load.
Never race the engine when it is cold.
Starting