Volvo TAD1345GE Betriebsanweisung Seite 33

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 82
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 32
Active and Inactive Faults
Active faults
At the same time, the fault is stored in the control unit
memory. When the fault has been attended to and the
ignition is switched off and on again, the fault disap-
pears as active.
DCU (Display Control Unit)
text !! ENGINE WARNING !! shown on the dis-
play.
CIU (Control Interface Unit)
the diagnostic lamp starts to flash.
”Easy Link” instrument
- the relevant lamp on the alarm panel lights up
- after the diagnostic button has been pressed,
the fault code is shown as text on the tachometer
display.
DU (Display Unit)
Either WARNING! or ALARM STOP (a buzzer
sounds) will be shown on the display, depending
on the severity of the fault.
Fault codes can also be read off using the
VODIA tool. For instructions, see “VODIA User’s
Guide”.
Inactive faults
DCU – the fault is indicated as passive
CIU – the diagnostic lamp goes out
DU – the fault message disappears (inactive
faults cannot be read out)
Easy Link – the lamp on the alarm panel goes
out
Operation
When a malfunction has occurred and the diagnostic
system has generated one or more fault codes, these
are read out differently depending on the equipment
used. Please refer to Fault code messages.
If the system indicates that a fault code has been
set:
1 Cut engine speed to idle, or shut the engine off.
2 For DCU/DU
Read the fault code from the display, please
refer to Reading fault codes via the DCU or
Reading fault codes via the DU.
For CIU
press the diagnostic button and read the fault
code, by observing the flashing of the diagnostic
lamp. Refer to Reading fault codes via the
diagnostic lamp, CIU.
3 Look up the fault code in the Fault Code Regis-
ter chapter and take the recommended meas-
ures.
Reading fault codes via the DU (Display Unit)
Depending on the severity of the fault the text, either
WARNING! or ALARM STOP (a buzzer sounds) will
be shown on the display
1 Press any button to come to the fault list. The
fault list shows operation hours and fault mes-
sage.
2 Look up the fault code in Fault Code Register
and take the recommended measures.
3 Press on ACK to acknowledge the fault code.
The display background will change color (the
buzzer stops sounding).
4 Press on EXIT to leave the fault list.
Fault Handling
7748641 06-2010 29
Seitenansicht 32
1 2 ... 28 29 30 31 32 33 34 35 36 37 38 ... 81 82

Kommentare zu diesen Handbüchern

Keine Kommentare