Coolant Filter, Change
NOTICE! Only applies to engines using Volvo Penta
Coolant (green). Engines using Volvo Penta Coolant
VCS are not fitted with coolant filters.
1 Turn the tap (1) 90° to stop the flow through the
coolant filter.
2 Remove the coolant filter with a suitable extractor.
Make sure that no residue from the old seal remains
in the housing.
3 Put a thin layer of engine oil on the new coolant filter
seal. Screw the coolant filter on by hand until the
seal comes into contact with the mating surface of
the filter bracket. Then tighten the coolant filter a
further 1/2 turn.
4 Turn the tap (1) 90° to release the flow through the
coolant filter again.
5 Start the engine and carry out a leakage check.
6 Switch the engine off and check the coolant level.
Refer to Coolant Level, Checking and Topping
Up page 56.